LD Calculator Lite History
Back
to LD Calculator Lite Page
-
Version 1.02 build 1
-Correction of the total neutral load in the Phase load list and Phase Load module.
Thanks to Tomy Neumann for the formula
-A right on a module icon on the Main toolbar will reactive a module when minimized.
-Truck load Print layout has been reformatted to give more room to the description field.
-Preference window should open without error
Known Bug: If the default printer is not a standard local
printer, the application can generate errors
when printing. The solution is to configure and set as default a
normal LPT printer.
-
Version 1.01 build 1
General
-When changing values of fields having a suffix like W for watts or V for Volts...
-The suffix disappears as you type the new value and reappear when leaving the field.
-Windows now resize properly under WinXP theme
-Many new fixtures added to the library
Photometric
-Add mF Min / Max
-Add Lumen Min / Max
Voltage Drop
-Distance calculation now work as intended (Percentage field).
Electrical Load List
-It's now possible to edit multiple entries at the same time
-When modifying a record, the index won't jump to the first record after editing.
-On the three-phase print layout the total of each phase is now display on the footer.
Weight Load List
-Add Weight in Lbs to the source list
DMX Calculator
-When adding multiple fixtures, the Fixture ID, Start address and port will be set according to last time you use the Add Multiple function.
Fixture Database
-Add new field Magnification mf Max so it's now possible to have both
Magnifying of Beam Max and Beam Min
-Magnifying fields are now calculated automatically as the Beam angle values are entered.
-Add New field Lumens Min so it's now possible to have both Lumens Max and Lumens Min
-
Version 1.00 build 4
DMX Calculator
-Column Channel can be sort now...
Electrical Load List
-In Single Phase, the amps X and Y now have the right values, before values were half of what they should be...
-The Balance phase and Balance Device now work as intended.
- Version 1.00 build 3
PhotoMetric
-New Interface easier to use
-Add Manufacturer Filter function
Electrical Basic Formulas
-Add Print Function
-Cosmetic change
Phases Load
-Add Print Function
-Cosmetic change
-Add Neutral Load
Electical Load List
-Complet re-write of this module
-Possibility to balance phase per device or per phase load
-Note: Old list are not compatible with new module
Voltage Drop
-Add Metric format
-Add Print function
-Add Drop Percentage
-Cosmetic change
Resistance Calculator
-Fix a problem entry value between 0.1 and 9.9
-Add Print function
-Cosmetic change
Rigging
-Add rigging point database
-Add Print function
-Add print formulas
-Cosmetic change
Weight Load List
-Fix bug that totals were not calculated when loading a list
-Fix some missing data when printing
-Fix misspelling of Height and Weight
-Cosmetic change
-Add Report name
Truck Load List
-Fix bug that totals were not calculated when loading a list
-Fix misspelling of Height and Weight
-Cosmetic change
-Add Report name
Converter
-Minus sign can be set in the temperature
-Numeric display format feature added to this module
-Cosmetic change
-Add PopUp Calculator
DMX Calculator
-Complete re-write of this module
-Menu bar added
-Auto Address function for all line or only selected line
-Added Channel field
-Auto Channel function for all line or only selected line
-Auto ID function when adding multiple fixture
Manufacturer Database
-Cosmetic change
-HyperLink to manufacturer website and email
-Add Print function
Fixture Database
-Add Print function
-Add Menu
Roadcase Database
-Cosmetic change
-Add Print function
Preferences
-Added posibilities to set a default User data folder
-Remove Numeric display format feature... move to The general converter
- Version 0.9v8r1
-Fix a problem with the print section of most module, so the LD Calculator should no longer crash when printing.
- Version 0.9v8
General
-Attempt to solve a problem with certain keyboard setting where the decimal point (.) is not working...
-Manufacturer Filter is now Re-apply on start-up
-The Status bar now display the value display format and precision.
Photometric
- Fix the Y calculation to include the Distance field.
Voltage Drop
Now you can choose to enter distance in feet or meter
Phase Load
-Voltage selection added (most worldwide used voltage in the drop list) ;
If a voltage is missing, please let me know...!
-Resistance information is now removed (less confusing)
Phase Load List
-Voltage selection Improved (most worldwide used voltage in the drop list)
Weight load list
-Print report is now correctly reporting kg and Lbs values....
Rigging
-The user interface has been re-done 0.9v7b2
-A new calculator has been add to calculate a rigging point according to the length of the bridle
-There's an increment option now, you can choose between 1 or 0.1.
-There's a checkbox to keep bridle length, point and beam height equal 0.9v7b2
-A rig visualizer has been add, Now it's possible to see in close proportion what the actual
Rig look like...
-Several improvement has been done to the formula to trap error...
- Version 0.9v7B3
Fix "On Change Weight" load value processing order, so now the display result fit with the actual input value
Toolbar
-Now the button tell you if the module is already open,
if the module is minimized or hidden, pressing the button will bring the module visible.
General Converter
-The Calculation is now redone when swap units.
DMX Address
-An Auto-Increment check box has been add. When checked the fixture number is increment by one every time the ADD button is press
-If a fixture address range is going beyond 512, it automatically move to the next port.
-A button "Start on Next port has been added.
-An Add Multiple fixture function has been implemented
-When the Fixture or Manufacturer column is not visible, it won't appear on the print report also
Resistance Color Code
-It's now possible to enter a resistor value to know it's color code
-The 0 (BLACK) got remove from the first column since it's did not exist in real life.
- Version 0.9v6
General
-The application no longer show an error message is the "Send to Tray Icon" feature was not enable
Photometric
-Now, a click on the "Manufacturer" or "Fixture name" box will sort the fixture list.
Phase Load Calculator
Single-Phase
-An error of calculation was found in the Single phase module, the Max KVA was half of the reality... sorry for that!
-New feature added to the Device section, now you can specify the working voltage Of the devices
-Now you can either enter the Maximum Amps per phase or the Max KVA available.
-The Clear values button was replace by a Clear Load Values, so only the load value are reset
Three-Phase
-A new section was add, now you can also enter load between X,Y,Z and the Neutral
-New feature added to the Device section, now you can specify the working voltage of the devices
-Now you can either enter the Maximum Amps per phase or the Max KVA available
-The Clear values button was replace by a Clear Load Values, so only the load value are reset
Rigging
-The arrow Up Down introduce in the previous version now work fine above value 1000.
Back
to LD Calculator Lite Page
|